Posted in | News | Lighting

Optical Harmonic Generation Can Become Non-Instantaneous

Ultrashort light pulses from modern lasers enable temporal resolution of even the fastest processes in molecules or solid-state materials. For example, chemical reactions can, in principle, be traced down to the 10-fs time scale (1 femtosecond (fs) = 10-15 s).

Ten femtoseconds correspond to a few oscillation cycles of the light field itself. Nevertheless, there is a class of optical processes that does not exhibit any measurable delay relative to the ultrafast light oscillation and which has been termed “instantaneous”. This class of processes includes nonlinear optical harmonic generation at multiple frequencies of the input field. This process is commonly used to generate the green light of laser pointers from invisible infrared light. These processes are normally used far away from a resonance to avoid losses.

In a collaborative effort, researchers of the Max-Born-Institut, the Weierstraß-Institut as well as the Leibniz-Universität Hannover now experimentally demonstrated for the first time that conditions exist where optical harmonic generation becomes non-instantaneous. Analyzing third-harmonic generation in titanium dioxide thin films, a lifetime of 8 fs was found, i.e., non-instantaneous behavior. Nevertheless, this process still qualifies as one of the fastest processes ever resolved with femtosecond spectroscopy.

Detailed theoretical modeling of these surprising findings indicates that this non-instantaneous response may only occur if there is a resonance of the third harmonic in the optical material. In turn, the generated material response persists to oscillate several cycles after the excitation has already ceased. Concomitantly, third-harmonic radiation is emitted. The process therefore appears like an atomic “resonance disaster”. Similar to mechanical oscillators, this atomic system therefore shows a non-instantaneous behavior.

These findings have important consequences for femtosecond measurement techniques and possibly also for ultrashort-pulse generation. These methods have always relied on an instantaneous nature of harmonic generation and related effects. Similar to soldiers who avoid marching in step on a suspension bridge, one therefore also has to carefully avoid optical resonances when measuring extremely short laser pulses.

Source: http://www.iqo.uni-hannover.de/

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.